undefined


Levels and Views
인쇄
마스터 
2011-09-23 09:19:25
조회:25246
답글지움수정 아랫글 목록 윗글
첨부 파일

 

 

Levels and Views

Attention: open in a new window.

In this article we are going to talk about Levels and Views. To simplify matters I’ll start off by talking about Levels, then go onto and Views and finally I will talk about the relationship between Levels and Views. As always, if you have any queries relating to these articles please ask away in our Forums. OK, let’s get started.

 

 

Levels

 

Levels are at the very heart of Revit. In order to use Revit effectively you need to be comfortable with what they are and how they are used. The easiest way to think about Levels is to envisage them as infinitely large planes, that are always horizontal and that have a set height in the Y direction. You can have as many Levels in your project as you wish. The minimum number of Levels you must have is one.

 

So what do we use Levels for? Well, anything that needs to be at a specific height. For example a floor plate, the top of a wall, the underside of a ceiling, the head of a window. Levels ARE used for setting the heights of your floors, but they are used for a LOT, LOT more than that.

 

When you first start a new Revit Project using the default Revit template, you are given two default Levels. Each of these has a Plan View already created….

 

 

The Plan View names are “Level 1” and “Level 2” as you may expect.

 

Now if we switch to an Elevation View, we can see the Level Markers for these two Levels……

 

 

The Level Markers contain the Level name and it’s absolute height in the 3D world.

 

Each Level can have a Plan View associated with it. For example, if you have a four storey building, you would probably like to have a Plan View for each of the Levels associated with four floors.

 

Let’s summarise what we have talked about so far:-

 

·         Levels are horizontal 2D planes with no boundary, that reside in the 3D model world

·         Levels MUST have a Name and a Height.

·         The Heights is measured in the Y axis in our 3D model world

·         You can have as many Levels as you like

·         Levels “may” have a Floor Plan View associated with them, but do not necessarily need to.

Views

 

Quite simply, Views are how we are able to see our 3D model (and 2D details!) and communicate it’s form and composition to others. Revit has many View Types for you to use. These include:-

 

·         Floor Plan Views

·         Elevation Views

·         Section Views

·         3D Views

·         Reflected Ceiling Plan Views

·         Drafting Views

·         Camera Views

 

A number of Views are created by default when you load the standard template. These can be seen in the Project Browser…..

 

 

You can see each individual View listed under it’s relevant category name. For example: “Level 1” and “Level 2” are Floor Plan Views and are listed under the “Floor Plans” category.

 

You can create additional Views as you need them by switching to the “View “ Design Bar and selecting the View type you need…….

 

 

Some Views can be generated automatically by Revit. For example, when you a Section Line (using the “Section” tool) Revit will automatically create an associated Section View. It will name this as “Section 1” by default. You can of course rename this to whatever you wish.

 

 

 

 

 

The Relationship between Levels and Views

 

As we said above, each Floor Plan View MUST have a Level associated with it. If we look at the properties for a Floor Plan View we can see…..

 

 

You can see that the “Associated Level” is set as “Level 1”. This is a parametric relationship. Ie if we change the height of Level 1, the Floor Plan View will always show the correct representation (ie what object you would expect to see on this Level)

 

When you create a new Level…..

 

 

Revit will automatically create a new Floor Plan View for this Level. However if you choose to create a new Floor Plan View (by use of the View Design Bar) Revit will need to know what Level this new View is to be associated with, hence the prompt…..

 

 

Other Views Types behave differently depending on what they are associated with. We mentioned Section Views. You CANNOT have a Section Line without a Section View. Consequently if you try to delete a Section Line you will get the following prompt….

 

 

Other View Types such as 3D Views are not associated with anything in particular so can be created and deleted at will. That concludes this short article on Levels and Views within Revit.


 

If you have any questions, comments or feedback relating to this article, please use our Forums. Registration takes approximately 1 minute and then you're free to start posting immediately.

답글지움수정인쇄 아랫글 목록 윗글

NEWS의 게시물 목록
번호 글제목 일시 조회 파일
35 ticon“착공 전 설계도서 오류 ‘0’”…BIM 투자 나선 대림산업 Open Url 20-07-06 115527  
34 ticon현대엔지니어링, 4대 영역서 스마트 건설 기술 비전 수립 Open Url 20-06-24 117709  
33 ticon[신간] 건설정보기술 BIM Open Url 20-06-15 109366  
32 ticon[월요기획] 공공시장 BIM 선택 아닌 필수 Open Url 20-06-03 107763  
31 ticon철도공단, 철도 건설사업에 BIM 전면 도입 Open Url 20-05-20 108760  
30 ticon“엔지니어가 직접 BIM 설계 수행해야”… 유신, BIM 전문가 육성 앞장 Open Url 20-05-19 105689  
29 ticon열흘만에 지은 中병원… 비결은 가상 실험실 ‘BIM’ Open Url 20-05-12 105501  
28 ticon스마트 건설 접목이 SOC 디지털화다 Open Url 20-05-11 105737  
27 ticon한국디지털교육원, BIM 전문인력 양성 박차 Open Url 20-04-07 106184  
26 ticon대림, 디지털 혁신 눈길… 업계 최초 전 공동주택 BIM 적용 20-04-07 104558  
25 ticon철도 BIM 의무화 R&D 착수 Open Url 20-03-17 104002  
24 ticon건기연, BIM·GIS 기반 '건축물 지진안전 통합관리시스템' 개발 Open Url 20-03-03 104311  
23 ticon건설회사 ‘프리콘(PreCon)’ 도입 확산 Open Url 20-03-02 105475  
22 ticon대림산업, 머신 컨트롤 기술·BIM 등 디지털 혁신 가속화 Open Url 20-02-17 104386  
21 ticon조달청, 건설정보모델링(BIM) 확대 가속 Open Url 20-02-05 103997